Development of the Universal Air Collector Design for Measuring the Flow Rate of Swirling Air Flow Using an Integral Thermoanemometer
DOI | https://doi.org/10.15407/pmach2024.01.006 |
Journal | Journal of Mechanical Engineering – Problemy Mashynobuduvannia |
Publisher | Anatolii Pidhornyi Institute for Mechanical Engineering Problems of National Academy of Science of Ukraine |
ISSN | 2709-2984 (Print), 2709-2992 (Online) |
Issue | Vol. 27, no. 1, 2024 (March) |
Pages | 6-14 |
Cited by | J. of Mech. Eng., 2024, vol. 27, no. 1, pp. 6-14 |
Authors
Oleh S. Tsakanian, Anatolii Pidhornyi Institute of Mechanical Engineering Problems of NAS of Ukraine (2/10, Pozharskyi str., Kharkiv, 61046, Ukraine), e-mail: tsakoleg1@gmail.com, ORCID: 0000-0002-1077-9818
Serhii V. Koshel, Anatolii Pidhornyi Institute of Mechanical Engineering Problems of NAS of Ukraine (2/10, Pozharskyi str., Kharkiv, 61046, Ukraine), e-mail: koshel@nas.gov.ua, ORCID: 0000-0003-3603-0909
Anna A. Kyryk, Hamelin Laie International School (Ronda 8 de Març, 178, 08390 Montgat, Barcelona, Spain), ORCID: 0009-0007-3899-7159
Abstract
Measurement of the swirling air flow rate and average speed of air at air distribution units of ventilation systems is a rather difficult task due to the fact that the air flow enters the measuring device at different angles. As a result, significant measurement errors can occur when using point thermoanemometers or other flow meters. The use of integral anemometers facilitates the measurement process. However, it is necessary to eliminate the errors associated with changes in the angle of the air flow to the sensing element of the measuring device. To do this, it is necessary to ensure a rectilinear structure of the air flow using a transitional air collector and rectifier. The aim of this paper is to develop a design of an air collector device that will allow to measure the flow rate of a swirling air flow. The objectives of the paper are to optimize the geometrical parameters of the air collector to ensure a rectilinear flow, minimize its dimensions and aerodynamic drag. The correctness of the air collector design was evaluated by matching the calibration characteristic of the probe of an integral thermoanemometer in the presence of a vortex diffuser in front of the air collector and in its absence. The proposed device has a rectangular shape and consists of a receiver, a rectifying grid, a chamber, an accelerating and stabilizing section, at the outlet of which a thermoanemometer probe is installed. The receiver and the accelerating section are tapered along their length, while the chamber and the stabilizing section have a constant cross-section. The rectifying grid is installed inside the chamber and has a square-shaped honeycomb structure. Several options of the air collector design with different geometrical parameters were studied using computer modelling. The dependence of aerodynamic drag on air flow was plotted. The optimal design of the air collector was chosen, for which a life-size physical model was created. The calibration characteristics of the measuring probe with an air collector were experimentally obtained when a swirling air flow was applied. The developed universal air collector allows the air flow rate measurement at the outlets of almost any air distribution devices of ventilation systems of buildings.
Keywords: air collector, thermoanemometer, air flow rate measurement, swirling air flow.
Full text: Download in PDF
References
- Borowski, M., Karch, M., Łuczak, R., Życzkowski, P., & Jaszczur, M. (2019). Numerical and experimental analysis of the velocity field of air flowing through swirl diffusers. XII International Conference on Computational Heat, Mass and Momentum Transfer (ICCHMT 2019), vol. 128. https://doi.org/10.1051/e3sconf/201912805003.
- Hu, S. C. (2003). Airflow characteristics in the outlet region of a vortex room air diffuser. Building and Environment, vol. 38, iss. 4, pp. 553–561. https://doi.org/10.1016/S0360-1323(02)00187-7.
- Li, A., Changqing, Y., Tong, R., Xin, B., Erwei, Q., & Ran, G. (2017). PIV experiment and evaluation of air flow performance of swirl diffuser mounted on the floor. Energy and Buildings, vol. 156, pp. 58–69. https://doi.org/10.1016/j.enbuild.2017.09.045.
- Lim, Y. B., Lee, S. M., & Lee, J. W. (2011). Characteristics of ventilating flow generated by a rotating swirler in a vortex vent. Journal of Fluids and Structures, vol. 27, iss. 3, pp. 427–437. https://doi.org/10.1016/j.jfluidstructs.2010.11.015.
- Kang J. H., Jung S. Y., & Kim, J. J. (2023). Effect of vanes on vortex characteristics of a vortex ventilation system. Journal of Building Engineering, vol. 76. https://doi.org/10.1016/j.jobe.2023.107160.
- Testo 420 – volume flow hood. URL: https://www.testo.com/en/testo-420/p/0563-4200.
- Temp. RH CO2 Anemometer. URL: https://www.az-instrument.com.tw/en/product-616302/Temp-RH-CO2-Anemometer-8919-AZ-Bulk-Order.html.
- Shkundyn, S. Z. & Bakharov, L. E. (2017). Integralnaja anemometrija – proryv v upravlenii ventiljaciej ugolnyh shaht [Integral anemometry – A breakthrough in ventilation control in coal mines]. Gornyj informacionno-analiticheskij bjulleten, no. S1, pp. 440–453 (in Russian).
- Thollander, P., Karlsson, M., Rohdin, P., Wollin, J., & Rosenqvist, J. (2020). Introduction to industrial energy efficiency: energy auditing, energy management, and policy issues. Academic Press, 380 p. https://doi.org/10.1016/C2018-0-01452-8.
- Ikeya, Y., Örlü, R., Fukagata, K., & Alfredsson, P. H. (2017). Towards a theoretical model of heat transfer for hot-wire anemometry close to solid walls. International Journal of Heat and Fluid Flow, vol. 68, pp. 248–256. https://doi.org/10.1016/j.ijheatfluidflow.2017.09.002.
- Saremi, S., Alyari, A., Feili, D., & Seidel, H. A (2014). MEMS-based hot-film thermal anemometer with wide dynamic measurement range. Proceedings of the IEEE Conference on Sensors (SENSORS’2014), (2–5 November 2014, Valencia, Spain), pp. 420–423. https://doi.org/10.1109/ICSENS.2014.6985024.
- Tsakanian, O. S. & Koshel, S. V. (2020). Integral thermo-anemometers for average temperature airflow measurement in duct, at anemostat outlets and in ventilation grilles. Journal of Mechanical Engineering – Problemy Mashynobuduvannia, vol. 23, no. 4, pp. 14–21. https://doi.org/10.15407/pmach2020.04.014.
- (2020). Intehralnyi termoanemometr-vytratomir [Integral thermal anemometer flow meter]: Patent no. 121840 Ukraine, G01F1/68, G01K17/06, no. a201908699; stated 18.07.2019; published 10.03.2020; bulletin no. 14/2020 (in Ukrainian).
- Tsakanian, O. S. & Koshel, S. V. (2021). Choosing a universal air collector design for a cylindrical-shaped hot-wire anemometer. Journal of Mechanical Engineering – Problemy Mashynobuduvannia, vol. 24, no. 2, pp. 6–15. https://doi.org/10.15407/pmach2021.02.006.
- Gorlin, S. M. (1970). Eksperimentalnaya aeromekhanika [Experimental aeromechanics]: Textbook for universities. Moscow: Vysshaya shkola, 432 p. (in Russian).
- Tikhomirov, K. V. (1977). Teplotekhníka, teplosnabzheniye i ventilyatsíya [Heat engineering, heat supply and ventilation]: Textbook for universities. Moscow: Stroyizdat, 288 p. (in Russian).
- Ventilyatory dlya kruglykh vozdukhovodov [Fans for round ducts]: Systemair catalog. 6 p. (in Russian). URL: http://www.systemair-ukraine.com/pdf/k-kv.pdf.
Received 23 October 2023
Published 30 March 2024